Separation

person Harald Tønnesen and Trude Meland, Norwegian Petroleum Museum
The job of the processing (treatment) platforms was to dewater the gas and condensate, and to control the flow rate and pressure of the gas being piped to Scotland.
— Illustration of the separation process.
© Norsk Oljemuseum

Flowlines linked these platforms, so that they could stand in for each other as required. Normally, however, gas from CDP1 was processed on TP1 and from DP2 on TCP2.

The gas system was divided into three equal trains, each comprising a separator, a compressor, a dewatering unit (glycol contactor) and a metering station. Each train had a daily capacity of 15 million standard cubic metres. Two were operational at any given time, with the third in reserve.

Separation

Gas from the drilling platform first entered a separator (free water knockout drum) which, as its name suggests, removed free water from the gas. This process involved leading the gas against a plate, where the water droplets lost kinetic energy, and then taking it on through a series of baffle plates which caused the droplets to coalesce. The liquid thereby fell to the bottom of the tank. While the gas continued to the compressor section, water and condensate (light oil) removed by the knockout drum were mixed in a stabilisation tank with condensate pumped from the drilling platforms. The denser water accumulated at the bottom of the tank before being transferred to an oil coalescer and pumped into well 3, while the condensate was pumped to another water coalescer and injected into the pipeline which carried the gas to Scotland. On arrival at the St Fergus terminal, the condensate was again separated from the gas.

The operator

Separasjon, drift,
Laboratory assistant Morten Jensen, in the laboratory at Frigg QP testing condensate. Photo: Elf Aquitaine Norge A/S/Norwegian Petroleum Museum

The first process undergone by the gas after it reached the processing platform was separation, where water and condensate were removed. One job for the operators was to check the separation tank, its valves, the stabilisation tank and other equipment related to the separator. The operator routinely drew off a small amount of condensate and prepared it for analysis.

A laboratory technician analysed the condensate, with the emphasis on measuring its water content. When the separator tank was full and the water content less than five per cent, one of the condensate pumps was started to pump the light oil into the pipeline to the UK together with the dry gas.